- 1
- Piece/Pieces,
- 4900.00 - 5500.00 USD ($)
- LCD
- 190-300VDC
- 50/60 Hertz (HZ)
- voltage/current sensor
- 5-40 Ampere (amp)
- AC-DC battery charger/ rectifier
- -40 ~ 60 Celsius (oC)
- -10 ~ 40 Celsius (oC)
- 154 Millimeter (mm)
- AC to DC
- 380 +/- 15% Volt (v)
- +/- 0.5 %
- 400*154*355 Millimeter (mm)
- 16 Kilograms (kg)
- 1 year
- A variety of current output optional, 5A 10A 20A 30A 40A
- Digital display panel
- Indication light
- Fault display
- Communication function
- Multiple protections including over/under voltage, current limiting, short-circuit, parallel protection, over-temperature protection.
- Modular design, N+1 backup,smooth expansion
- Perfect monitoring function, high intelligent
- Main monitor items: turn on/off, output voltage regulation, output current limit set, automatic battery management
- Automatic Battery management and maintaining: real-time monitoring of battery pack terminal voltage, charge/discharge current, automatic even and float charging & regular even charging
- Automatic temperature compensation
- Hot plug, easy to replace and safe
- Modular
- Design, N+1 pc(s) backup;
- The friendly man-machine interface. LED screen
- RS-485 communication interface, achieves 4 remote control function
- High efficiency, up to 95%-96%;
- Light weight, Small size
- After the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;
- Unequal current ratio of parallel connection<+/-3%, can ensure twenty modules work well by parallel connection.
- Function against reverse connection
- ED digital screen
- Output over voltage protection
- Output current limiting protect
- Output short-circuit protection
- Module parallel protection
- Over-temperature protection
- Output over-current protection
Technical Specifications
Module Code | 230D05ZZ - 3 | 230D07ZZ - 3 | 230D10ZZ - 3 | 230D20ZZ - 3 | 230D20NZ - 3 | 230D30NZ - 3 | 230D40NZ - 3 | |
rated output current(A) | 5 | 10 | 10 | 20 | 20 | 30 | 40 | |
power(KW) | 1.5 | 2.1 | 3 | 6 | 6 | 9 | 12 | |
weight(kg) | 5.2 | 9 | 9 | 16 | 10.5 | 19 | 19 | |
cooling type | natural cooling | fan cooling | ||||||
Internal radiator temperature rise | 30 | 20 | ||||||
range of input voltage AC(VAC) | min | 304 | ||||||
Typical value | 380 | |||||||
max | 456 | |||||||
range of the output voltage(VDC) | min | 190 | ||||||
Typical value | 220 | |||||||
max | 300 | |||||||
Voltage Stabilizing accuracy | +0.5% | |||||||
Current Stabilizing accuracy | +1% | |||||||
PFC | +0.93 | |||||||
Efficiency | +95% | |||||||
noise(dB) | <50 | |||||||
Storage temperature () | min | -40 | ||||||
Typical value | 25 | |||||||
max | 60 | |||||||
working temperature () | min | -10 | ||||||
Typical value | 25 | |||||||
max | 40 | |||||||
Unbalance rate of load sharing | +3% | |||||||
Soft start time(s) | 3~8 | |||||||
Ripple coefficient | 0.2% | |||||||
Load grade | Continuous working with Grade I(100%) rating output current | |||||||
Automatic current limiting | The output current does not increase infinitely. When output current is over threshold, there will be limited constant current output. The maximum output current of is limited to 105% of the rated output current. | |||||||
Output over voltage protection | No output, threshold (320+5VDC), self recoverable | |||||||
output short circuit protection | When short circuit, the module will protect itself from broken. Self recoverable |
- Ningbo/Shanghai
- 6000 Per Month
- 7 Days
- Yes
- Contact us for information regarding our sample policy
- Packing of battery charger is strong honeycomb carton
- All India
- CE(EMC&LVD), SAA(AS4777&AS3100), G83, G59, VDE ARN 4105, UL1741, CSA22.2, ISO9001
Building 13-2 Botong Huigu, No. 66 Binhai South Four Road, Yueqing Economic Development Zone, Yueqing, Zhejiang, 325604, China
Phone :+8613175696608